Magnetization
 
The magnetic polarization of a material produced by a magnetic field (magnetic moment per unit volume).

See also Macroscopic Magnetization Vector.
spacer
 
• Related Searches:
    • Precession
    • Magnet
    • Excitation
    • Magnetic Forces
    • Longitudinal Magnetization
MRI Resources 
Stent - Diffusion Weighted Imaging - Liver Imaging - Equipment - Pediatric and Fetal MRI - Contrast Enhanced MRI
 
Pulse Length
 
Time duration of a pulse. For an RF pulse near the Larmor frequency, the longer the pulse length, the greater the angle of rotation of the macroscopic magnetization vector will be (greater than 180° can bring it back toward its original orientation). For an RF pulse of a given shape as a function of time, the longer the pulse length, the narrower the equivalent range of frequencies in the pulse will be.
spacer

• View the DATABASE results for 'Pulse Length' (2).Open this link in a new window

 
Further Reading:
  News & More:
Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.
Tuesday, 1 August 2006   by www.ncbi.nlm.nih.gov    
MRI Resources 
Implant and Prosthesis - Corporations - Shielding - NMR - MRI Physics - Mass Spectrometry
 
Pulse, 180°
 
RF pulse designed to rotate the macroscopic magnetization vector 180° in space as referred to the rotating frame of reference, usually about an axis at right angles to the main magnetic field. If the spins are initially aligned with the magnetic field, this pulse will produce inversion. Also called P Pulse.
spacer
 
Further Reading:
  Basics:
Clinical evaluation of a speed optimized T2 weighted fast spin echo sequence at 3.0 T using variable flip angle refocusing, half-Fourier acquisition and parallel imaging
Wednesday, 25 October 2006
MRI Resources 
Software - MRI Technician and Technologist Career - Fluorescence - Developers - Implant and Prosthesis - Mobile MRI Rental
 
Pulse, 90°
 
RF pulse designed to rotate the macroscopic magnetization vector 90° in space as referred to the rotating frame of reference, usually about an axis at right angles to the main magnetic field. If the spins are initially aligned with the magnetic field, this pulse will produce transverse magnetization and a FID. Also called P/2 Pulse.
spacer
MRI Resources 
Homepages - MRI Training Courses - Pacemaker - IR - Universities - MRI Technician and Technologist Career
 
Radio Frequency Pulse
 
A pulse is a rapid change in the amplitude of a RF signal or in some characteristic a RF signal, e.g., phase or frequency, from a baseline value to a higher or lower value, followed by a rapid return to the baseline value. For radio frequencies near the Larmor frequency, it will result in rotation of the macroscopic magnetization vector. The amount of rotation will depend on the strength and duration of the RF pulse; commonly used examples are 90° (p/2) and 180° (p) pulses.
RF pulses are used in the spin preparation phase of a pulse sequence, which prepare the spin system for the ensuing measurements. In many sequences, RF pulses are also applied to the volumes outside the one to be measured. This is the case when spatial presaturation techniques are used to suppress artifacts. Many preparation pulses are required in MR spectroscopy to suppress signal from unwanted spins. The simplest preparation pulse making use of spectroscopic properties is a fat saturation pulse, which specifically irradiates the patient at the fat resonant frequency, so that the magnetization coming from fat protons is tilted into the xy-plane where it is subsequently destroyed by a strong dephasing gradient.
The frequency spectrum of RF pulses is critical as it determines the spatial extension and homogeneity over which the spin magnetization is influenced while a gradient field is applied.
spacer

• View the DATABASE results for 'Radio Frequency Pulse' (16).Open this link in a new window

 
Further Reading:
  News & More:
MRI Safety: Monitoring Body Temperature During MRI
Thursday, 4 August 2011   by www.diagnosticimaging.com    
MRI Resources 
Pregnancy - Spine MRI - IR - Diffusion Weighted Imaging - Databases - MRI Accidents
 
previous      6 - 10 (of 10)     
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 1 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]